Selection basis of the DIN valve connector
1. Select the solenoid valve according to the pipeline parameters: diameter specification (i.e. DN) and interface mode
1) Determine the diameter (DN) according to the internal diameter size or flow requirements of the on-site pipeline;
2) Interface mode: generally, flange interface shall be selected if it is > DN50, and it can be freely selected if it is ≤ DN50.
2. Select the material and temperature group of the solenoid valve according to the fluid parameters(DIN valve connector)
1) Corrosive fluid: corrosion resistant solenoid valve and all stainless steel should be selected; Edible ultra clean fluid: food grade stainless steel solenoid valve should be selected;
2) High temperature fluid: the solenoid valve made of high temperature resistant electrical materials and sealing materials shall be selected, and the piston structure type shall be selected;
3) Fluid state: it must be distinguished from gas state, liquid state or mixed state, especially when the diameter is greater than DN25;
4) Fluid viscosity: generally, it can be arbitrarily selected below 50cst. If it exceeds this value, the high viscosity solenoid valve shall be selected.